Analysis and solution of peristaltic pump hose and pump tube damage

July 15, 2023
Peristaltic pump hoses can be used as a peristaltic pump consumable in use. What are the causes of these damages?
1. From the shape of the damaged hose, the cause of the damage: the hose is completely flattened, the rebound ability is lost, the wall thickness of the hose is thinned, and the surface is seriously worn. This phenomenon is usually caused by the stuck wheel, the surface of the peristaltic pump block contacting the pump tube and the impurities on the runner, and the rotation speed is too high. After the runner of the peristaltic pump head is stuck, the runner of the peristaltic pump directly scrapes through the peristaltic pump hose, which increases the friction of the surface of the hose, causing the surface temperature of the hose to rise very high and the surface of the hose to be worn too high. The temperature also causes the hose to lose its elasticity. In extreme cases, the temperature generated above 140 degrees may cause the hose to melt and deform.
Solution: Pay attention to check whether the operation of the peristaltic pump head runner is flexible; pay attention to cleaning the pump head pressure tube surface; appropriately reduce the speed of the peristaltic pump operation.
2. From the size and shape of the damaged peristaltic pump hose, the cause of the damage: the peristaltic pump hose may carry different liquids, and some liquids may corrode and dissolve some of the hoses. If we see that the peristaltic pump hose becomes brittle, hard, loses its elasticity, discolors, swells, breaks, etc., it is usually caused by the hose being unable to deliver the liquid.
Solution: Find the hose material that will not be corroded by the liquid that is transported by itself. Shenchen Peristaltic Pump Co., Ltd. has a wide range of pump tubing materials to choose from, which can provide chemical compatibility test data for most liquids, providing detailed information. A deep chemical table is available to help you choose the right hose. You can also take some samples of the hose to do a soak test to make sure the hose is not corroded by liquids.
3. See the damage of the peristaltic pump hose from the damaged break. Cause: If the damaged peristaltic pump hose is a sharp cut like a knife, it is usually the runner and flange of the peristaltic pump head. Cut off. The reason for this damage is usually because the hose inside the pump head is too long. When the pump head of the peristaltic pump is running, the hose shakes in the pump head and contacts the flange edge of the runner. The flange is continuously rubbed and soft. tube. This process of damage can be very fast and usually breaks completely in about ten minutes. Along with the damage of the pump tube, a lot of hose slag is generated in the pump.
Solution: 1. When installing the pump tube, make sure that the pump tube in the pump head is straightened, and there will be no excessive hoses in the pump head. 2. At the same time, put a special plastic clamp on the inlet and outlet of the hose pump near the pump head tube to prevent the peristaltic pump hose from loosening during operation.
Uns von uns aussagen

Autor:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

beliebte Produkte
Sie können auch mögen
Verwandte Kategorien

Mail an Lieferanten

Fach:
E-Mail-Adresse:
Nachrichten:

Ihre Nachricht MSS

Uns von uns aussagen

Autor:

Mr. Bruce Tang

Phone/WhatsApp:

+8613773149257

beliebte Produkte

Zuhause

Product

Whatsapp

Über uns

Anfrage

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

senden