Modell: I0.60T40W
Marke: Macxi
Zertifizierung: Ce
Power Source: Electric
Place Of Origin: Jiangsu, China
Customized Support: Oem, Odm, Obm
Structure: Gear Pump
Brand Name: Macxi
Outlet Size: G1/8
Horsepower: 40 W
Power: 40 W
Ambient Temperature: -40℃-70℃
Pressure: 4 Bar
Voltage: 24 V
Warranty: 1 years, 20000 hours
Motor: Built in drive DC brushless
Gear Material: Tungsten Steel
Fluid Viscosity: 0.2-1500cps
Model Number: I0.60T40W
Speed: 500 - 5000 rpm
Flow Rate: 0.60 ml/rev
Pump Body Material: SS with Titanium nitride coating
Anwendung: Automotive Industry, Developing World Water Solutions, Drinking water treatment, Food and Beverage Industry, Industrial Utilities, Irrigation and Agriculture, Pharmaceutical industry, temperature control, Wastewater Transport and Flood Control
Verpakung: Standard -Exportkarton mit Kundenversandzeichen
Produktivität: 50000/year
Transport: Land,Ocean,Air
Ort Von Zukunft: Jiangsu, China
Unterstützung über: 30000 Piece/Pieces per Year
Zertifikate : ISO 9001
HS-Code: 8413609090/8443992990/8413910000
Hafen: Shanghai
Zahlungsart: T/T
Incoterm: FOB,CFR,EXW
Produktmodellbeschreibung
Produktanweisung:
Der 1,400 -Mesh -Filter muss am Einlass der Zahnradpumpe installiert werden.
2. Diese Zahnradpumpe eignet sich lange Zeit für den kontinuierlichen Betrieb und kann nicht unter dem Zustand des häufigen Starts und Stopps verwendet werden.
3. Verwenden Sie eine kleine Menge mit Medium, um das Zahnrad aus dem Einlass der Zahnradpumpe zu schmieren.
Produktmodellauswahlanweisung:
Pump Head |
Motor |
||
I |
0.07 |
S |
40W |
"I" means the Integrated Structure |
Pump revolution, Unit: ml/rev, note ① for details |
Pump body materials, note ② details |
Motor type and Power |
Anmerkungen:
1. Pumpenausgangsvolumen: 0,07,0,15,0,3,0,6,0,9,1,5,0,6., 12,0 (Einheit: ML/Rev)
2. "S" bedeutet, dass Pumpenkörpermaterial 316L, Zahnrad und Wellenhülle sind, die mit PTFE versiegelt sind, die anderen sind 316 l.
"T" bedeutet, dass Pumpenkörpermaterial 316 l, Zahnrad und Welle sind Wolframstahl, Wellenhülse ist ein Peek, Dichtung mit PTFE, die anderen sind 316 l.
"P" bedeutet, dass Pumpenkörpermaterial PPS ist, Gear Materail und Wellenhülle sind Peek, Versiegelung mit FFKM, die anderen sind Hastelloy.
"H" bedeutet, dass die Pumpenkörpermaterialien Hastelloy, die Zahnrad- und Wellenhülle ist Peek, die Versiegelungsmaterial 316L Pumpkopf.
Produktmodell: I0.60T40W
Produktdiagramm:
Produktparameter:
Pump Model |
Motor Type |
L1(mm) |
L2(mm) |
Pressure(bar) |
Weight(kg) |
Rated Current(A) |
Imp.&Exp. Size |
Flow(L/H) |
I0.15T |
40W |
95.4 |
32.8 |
8 |
0.73 |
2.5 |
G1/8 |
4.5~45 |
I0.30T |
95.4 |
32.8 |
0.73 |
9~90 |
||||
I0.60T |
95.8 |
36.9 |
4 |
0.74 |
18~180 |
|||
70W |
108.1 |
36.9 |
8 |
0.89 |
3.3 |
18~180 |
Pump Head Parameters |
Motor Parameters |
Motor wiring definition |
|||
Fluid Viscosity |
0.2-1500cps |
Drive Type |
Built in drive DC brushless |
Red |
+24V |
AAmbient TemperAture |
-40℃-70℃ |
Rated Voltage |
24V |
Black |
0 |
Static sealing |
PTFE |
Speed regulating voltage |
0-5 (0.35V ON 0.3V OFF) |
Brown |
Speed control signal 0-5V input |
Pump Body |
Stainless steel with Titanium nitride coating |
Speed rpm |
500-5000rpm |
Blue |
5V level, square wave, 2 pulses per revolution |
Gear |
Gear and gear shaft are WC |
Working system |
Continuous |
|
|
Bemerkungen:
Der OEM -Service ist gemäß Ihrer Anfrage durchschnittlich.
Die Spezifikationen dienen nur als Referenz, um Details zu überprüfen. Bitte wenden Sie sich bitte an uns.
(Number of phase) |
N |
3 |
(Rated Voltage) |
VDC |
24(8-30VDC) |
(Rated Power) |
W |
40W |
(Speed regulating voltage) |
VDC |
0-5 (0.35V ON 0.3V OFF) |
(Range of speeds) |
RPM |
500-5000 |
(Maximum current) |
A |
2.2A |
(Instantaneous protection current) |
A |
5A |
Verkabelungsanleitungen
Red |
+24VDC |
Black |
GND |
Brown |
Speed control signal 0-5V input |
Blue |
5V level, square wave, 2 pulses per revolution |
Sichere Funktionen
Betriebsschutz: Wenn der Motorlaufstrom den Grenzstrom von 2,2A erreicht, startet der Motorantrieb den Schutz und läuft nicht mehr.
Verriegelter Rotorschutz: Wenn die Pumpenkörpers gesperrt ist, startet das Antrieb die Schutzfunktion und schneidet die interne Stromversorgung des Motors ab.
Software- / Hardware-Überstromschutz: Wenn das System erkennt, dass der sofortige Strom von Software und Hardware im Motor größer als 5a ist, startet das Laufwerk den Schutz.
Hall -Fehlerschutz: Wenn der Motorhalssensorfehler startet, startet der Motor mit dem Laufen des Schutzes, um das Verbrennen des Motors zu verhindern.
Unter Spannungsschutz: Wenn die Betriebsspannung niedriger als der angegebene Bereich ist, wird der Betrieb gestoppt.
Leistungsdaten
HINWEIS: Die Ventiltür ist vollständig geöffnet und unter Bedingung ohne Ladung getestet
HINWEIS: Die Ventiltür ist unter Volllastbedingungen blockiert und getestet
Produktgruppe : Integrierte Zahnradpumpe > 0,60 ml/Rev -Gearpumpe
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.